CONFIGURATION
3-2
SIG-QG-20-02 JANUARY 2021
Version : A.2
3.1.2 Configuration Menus (GCP 4000)
• Template Programming displays only the configuration items and settings that are usually
required for standard applications
• Basic Configuration is used to set up the non-vital site information, for example site name,
milepost, DOT number, etc.
• Predictors Configuration is used to configure associated predictors
• GCP Programming is used to set the vital parameters that control the operation and the 4000
GCP
• Island Programming is used to configure the associated islands
• AND Tracks Configuration is used to configure associated ANDing
• ADVANCED Programming is used for Out Of Service (OOS), internal I/O, and other advanced
programming configuration
• SSCC Programming is used to configure associated SSCCs
• IO Assignment assign Input / Outputs
• SEAR Programming used to configure SEAR
• SITE Programming is used for site-specific configuration
• Display Programming is used to set non-vital settings related to the operation of the display
3.2 SITE CONFIGURATION
This screen is used to set the non-vital site information, for example, site name, milepost, DOT number,
etc. The GCP 3000+ contains a reduced list of parameters. To edit, first unlock and confirm local user
presence (see Section 6.1.5.1). The fields will now be editable.
To change the values in a field, type in the new value and then press the Save button. Multiple fields on
this page can be edited. If there are unsaved changes and a new screen is selected, the WebUI will
prompt the user to save or discard the changes.
To discard changes without saving, press the Discard button.