EasyManua.ls Logo

Silca Triax Quattro - Messages about Spindle

Silca Triax Quattro
118 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating Manual - English Triax QUATTRO
Copyright Silca 2011 - 73 -
It is important to replace the battery as allows LOG
events to be saved with the right date/time.
ALARM 12
Flat clock battery:
see operating manual for
replacement.
Download a more up-to-date SW version.
ALARM 13
Machine firmware is more
up to date than the software
in the USB PEN !
6.3.1 MESSAGES ABOUT SPINDLE
The message indicates that there is no connection
between the mother board and driver board.
The problem could be caused by the mother board or the
connection cable between the mother board and spindle
driver board or by the spindle driver board.
ALARM 5
SPINDLE DRIVER ALARM
No communication between mother
board and spindle drive.
See operating manual
Effect : Motor not turning
Cause : Short circuit on spindle motor or board
power loss.
Driver damaged.
Check AZ motor board connectors
ALARM 6
SPINDLE DRIVER ALARM
Spindle speed not detected :
motor locked
See operating manual
Effect : Free-running motor does not reach the
rotation speed required for cutting
Cause :
Motor not working
Driver board not working
Driver board with wrong parameters.
ALARM 7
SPINDLE ALARM
Spindle rpm not reached after
activation!
See operating manual
Effect : Motor under excessive strain during
cutting
Cause : Cutter does not cut.
The combination rpm/cutting speed
is not compatible: select a more suitable
combination.
ALARM 8
SPINDLE ALARM
Excessive cutter strain during
cutting!
See operating manual

Table of Contents