2. Press the <ALARM ACK> key. R& and follow the instructions on the alphanumeric display. Pertinent
report data is given as shown below.
I 1
FIRST FLOOR EAST WING
ROOM 31
Press ACK key to acknowledge ALARM +
PULL STATION
ALARM 4
ALTWiFil&ING
3. Press <ALARM ACK> key again. Read the report data. Repeat this procedure to review all reports. Reports
are displayed in chronological order. Note that the following items have occurred:
a. Tone-alert is silenced
b. SYSTEM ALARM LED is ON, but is no longer flashing.
HOW TO SILENCE THE ALARM SIGNALS
Press the <ALARM SILENCE> key and read the display. The display should show the following message.
I
ALARM SILENCE IN PROGRESS...
I
I
1
HOW TO RESET THE SYSTEM
When the alarm condition has been cleared, restore or replace all affected devices (pull stations, smoke detectors,
etc.) in accordance with the instructions provided with each device. Then, do the following:
1. Press the <SYSTEM RESET> key. After a delay, the SYSTEM ALARM LED will begin to flash, and the
tone-alert will begin its pulsing sound.
2. Press the <ALARM ACK> key m. After a delay, the system should show the following message.
I
SYSTEM IS NORMAL
8:27:34
MON 7 DEC 92
I
ESSENTIAL ALARM CONDITION KEYS
The essential keys for alarm conditions are the <ALARM ACK> (Alarm Acknowledge), <ALARM SILENCE>, and
the <SYSTEM RESET> keys. The remaining keys are concealed by the interface panel access door and are
associated with advanced system functions. (See Section 9, Advanced Functions.)
ALARM ACKNOWLEDGE KEY
The <ALARM ACK> key is located directly under the SYSTEM ALARM LED. Pressing the <ALARM ACK> key
(m for Individual Acknowledge or once for Global Acknowledge) causes the SYSTEM ALARM LED to change
from flashing to steady ON and silences the tone-alert. Pressing the <ALARM ACK> key does the following:
l
Selects the next unacknowledged alarm point in the list for display (Individual Acknowledge)
l
Acknowledges the displayed point or acknowledges all points on the list (Global Acknowledge)
l
Scrolls the points chronologically after all points have been acknowledged.
11
firealarmresources.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Simplex 2500 and is the answer not in the manual?

Simplex 2500 Specifications

General IconGeneral
BrandSimplex
Model2500
CategoryFire Alarms
LanguageEnglish

Related product manuals