SKOPE TME/SKT ActiveCore
Replacement Procedures
Service Manual
Replacing the
Unit
The SKOPE ActiveCore refrigeration unit is interchangeable between bottom and top mount
ActiveCore fridges.
When changing from a bottom mount fridge to a top mount fridge, an evaporator lid, strap
brackets and hold down brackets must be fitted to seal the top of the evaporator tub, and to fix
the unit to the top of the cabinet.
New spare part refrigeration units supplied by SKOPE are not supplied with the evaporator tub
lid, top strap brackets and hold down brackets. When replacing a faulty top mount refrigeration
unit, retain these parts for use on the new spare part replacement unit.
The evaporator tub lid, top strap brackets and hold down brackets can be ordered in addition
to the refrigeration unit if required. See page 50 for spare part numbers.
Sign side
Electronic
controller assembly
Sign back strip
Electrics
cover
Mains and
cabinet plugs
Sign side
Top sign