41
SKOPE TME/SKT ActiveCore
Replacement Procedures
Service Manual
Compressor
Electrics
The compressor electrics are located on the front of the compressor (see image below).
To access the compressor electrics, remove the refrigeration unit (see page 34) and unit cover
(see page 37). The capacitor unclips from the relay cover, and the relay cover unclips from the
compressor.
Pressure
Switch
A manually resettable high pressure switch is fitted to protect the refrigeration unit from
over-pressure (high temperature) conditions.
Conditions that may activate the high pressure switch include:
High ambient conditions (ensure adequate ventilation)
Lack of refrigeration ventilation
Blocked or restricted condenser or condenser filter
Faulty condenser fan motor
Poor refrigeration unit sealing
Procedure 36: To reset the high pressure switch
1. Isolate the fridge from the power supply and remove the refrigeration unit (see page 34).
2. Determine and eliminate what caused the high pressure switch to activate.
3. Remove the refrigeration unit cover.
4. Reset the high pressure switch by pressing the red button on the side of the refrigeration unit.
5. Reassemble and test for correct operation.