5 Maintenance
Cleaning
Cabinet Wipe the inside and outside of the cabinet with a damp cloth, taking care to keep moisture
away from electrical parts. As with any maintenance, ensure the fridge is unplugged from the
power supply before cleaning.
Condenser
Coil and
Optional Filter
To ensure trouble-free performance, the condenser coil must be kept clean. We strongly urge
monthly cleaning with a soft brush to remove dust and fluff. A more thorough cleaning is
required by qualified service personnel every six months. The condenser coil must be kept
clean for efficient and reliable operation.
WARNING
Unplug the fridge from the power supply before cleaning the
condenser filter and condenser coil.
Procedure 41: To clean the condenser coil and optional condenser filter
1. Isolate the fridge from the power supply.
2. Remove the front panel from the top of the
cabinet by swinging it out and off. Lit sign front
panels will also need to be unplugged.
3. If the fridge is fitted with a filter, remove the filter
from the front of the refrigeration unit and clean
with a vacuum cleaner and cold water, and
shake excess water off before refitting. Do not
apply hot water, blow dry or place in dishwasher.
If necessary, discard and use new air filter.
4. Brush the condenser coil with a soft brush to
remove any dust and fluff.
5. Refit or replace the filter (where fitted), refit the sign panel and reconnect to the power supply.
Front panel
Condenser filter
Condenser coil