72
Troubleshooting
Service Manual
SKOPE TME/SKT ActiveCore
• Moisture build up on
door or exterior.
• High humidity.
• Check ambient operating temperature and reposition fridge
if necessary.
• Frequent door opening. • Limit door openings.
• Door not closing properly. • Check and clean door gasket.
• Fridge door does not
shut properly.
• Fridge is on an uneven surface. • Level the fridge.
• Door is obstructed. • Check shelves and product.
• Warm cabinet
temperatures
• Compressor operating
for long periods (more
than 1 hour)
• Blocked condenser • Clean the condenser filter (if fitted) and condenser.
• Poor ventilation around
refrigeration unit
• Ensure the cabinet has good ventilation around the
refrigeration unit.
• Ensure the cabinet is within the maximum operating
temperature.
Table 35: Cabinet and unit troubleshooting (continued)
Problem Possible cause Repair