Shenzhen Skyshl Technology Co.,LTD.
Sales email: sales1@skyshl.net After Sales email:af@skyshl.net Website:www.skyshl.net
SS413F Optical Fiber Fusion Splicer Userās Manual
V
Reinforcement of fiber splices
4.7.1 Selecting the heater mode according to heat-shrink sleeve material
<1> Different heat shrink sleeves have different specifications and sizes. When the
users reinforce the fiber splice point, matching heat shrink sleeve shall be used.
The heat shrink sleeve shall be operated according to the material type of the heat
shrink sleeve used at present. The user shall choose a suitable heater mode.
<2> In "Select heater parameter files" screen, there are a total of 9 sets of different
kinds of heat shrink sleeve modes, which can be selected, used and edited by the
user, as shown in following figure.
Heater mode description:
Heating parameter file name is up to 16 characters for users.
Setting material of heat shrink sleeves: Standard,Micro 250,
Micro 400, Micro 900 and Connector and so on.
Set the length of heat shrink sleeves: 60mm, 40mm, 20 mm, etc.
Some length types are optional.
Heating control includes "Automatic" or "Manual" optional
function.