V
<2> Determine the fiber splice point is placed at the middle position of heat-shrink
sleeve. Then the heat shrink sleeve is put into the center position of the heating
groove. Straighten gently the fiber. Close the heater transparent window cover
(right press plate) and the heater clamp (left press plate).
<3> Press the keypadbutton to start heating. Heating processes are
composed as follows: Start heating-up (LED red indicator), constant temperature
stage (LED green indicator), cooling stage (LED red indicator). When heating is
complete, the buzzer sounds. The heating indicator LED (red) is turned off
automatically. If pressing button in heating process, the heating process
will be terminated.
<4> After opening the heater transparent window, the fiber has been protected by
the heat shrink sleeve and the fiber can be removed.
<5> Observe heat shrink sleeve after heating, qualified product inside is free of
bubble and dust.
B.Automatic heat control
● Heat shrink sleeve may be stained on the heating bottom plate of the
heating groove,in this case, remove the heat-shrink sleeve by a cotton swab.
● Heater temperature in heating process is high. Do not touch the heating
groove and heat-shrink sleeve .
● The reinforcing core of the heat shrink sleeve is placed
on the bottom and the optical fiber shall not be distorted .