49
Shenzhen Skyshl Technology Co.,LTD.
Sales email: sales1@skyshl.net After Sales email:af@skyshl.net Website:www.skyshl.net
SS413F Optical Fiber Fusion Splicer Users Manual
V
E.Press button again.Press button to select "open" function. Press
button and come back to the window of "edit heating parameter file".Press
continuously button to return to the readiness window.The heater of the
splicer will always be at "temperature stay: 60" thermal equilibrium condition,
F.The factory default "temperature stay" of the heater of the splicer is at 60 .
Setting range: 55-165 . The operator shall select the applicable temperature
according to the application requirement of low temperature environment.
<2> Select heating parameter files
If the operator adopts "Micro- 900" heat shrink sleeve, in order to meet the quality
requirements, the operator shall select the heater mode of
corresponding "material category". The steps of "select" heating parameter are as
follows: