User Guide
21
After turning on the system, this reboots and the first thing displayed on the
screen is the logotype and software version of the equipment. Once rebooted,
the current setup of the equipment is graphically shown on the identification
screen.
Other status indicators
The blue Remote indicator flashes on and off when the equipment enters into
firmware update mode. It will remain on when the remote communication has
been established.
The permanent yellow indicator Trip. Ovd indicates an overload in the output.
This may be due to different reasons such as the load value being too high for
the required current. And, when it flashes, it indicates overload in the l.t. product.
This indicator will be deleted when the power is switched on and if it persists, the
source of the overload will be activated again.
The yellow indicator Trip. Th indicates thermal overload of the unit. Whilst this
indicator remains on, it will not be possible to give power. When the unit
recovers the appropriate work temperature it will go off.
The red indicator, Out, indicates that the equipment is injecting, regardless of
the generation mode set.