8 Troubleshooting
8�1 SolarMax Service Center
If you have technical questions or difculties, our Service Center will be happy to help you.
To do that we need the following information:
Device type
Serial number (S/N)
Installation location
Information on the current failure (warning, status message, plant documents, etc.).
Contacting the SolarMax Service Center
The contact details of the SolarMax Service Center can be found on the back of this
instruction manual.
Sputnik Engineering AG
Länggasse 85
CH-2504 Biel/Bienne
8�2 Diagnosis and actions
The following tables describe possible actions for remedying faults. If the actions sug-
gested do not correct the fault, please contact the SolarMax Service Center.
82�1 General troubleshooting
Problem Cause Actions
The graphics display
remains blank
The DC disconnector is switched
off.
Switch on the DC disconnector.
The irradiation is too low. Wait until irradiation is high
enough.
All DC input conductors (strands)
are interrupted.
Check the PV generator and
eliminate the interruption.
It is possible that the inverter is
defective.
Contact the SolarMax Service
Center.
The graphics display only
ashes briey.
The irradiation is too low. Wait until irradiation is high
enough.

Table of Contents