Version 5.2 Sourcefire 3D System Installation Guide 180
Hardware Specifications
Sourcefire 8000 Series Devices
Chapter 6
The power supply modules are located on the rear of the appliance. The
8000 Series Power Supply LEDs table describes the LEDs associated with the
management interface.
The 8000 Series RJ45 to DB-9 Adapter Pin-Out table list the signals on a typical
DB-9 serial connector and the corresponding pins on the device’s RJ45 serial
connectors. You can use this table to construct an adapter for serial connections.
8000 Series Power Supply LEDs
LED DESCRIPTION
Off The power supply is not plugged in.
Amber No power supplied to this module.
OR
A power supply critical event such as module failure, a
blown fuse, or a fan failure; the power supply shuts down.
Blinking amber A power supply warning event, such as high temperature
or a slow fan; the power supply continues to operate.
Blinking green AC input is present; volts on standby, the power supply is
switched off.
Green The power supply is plugged in and on.
8000 Series RJ45 to DB-9 Adapter Pin-Out
DB-9 PIN SIGNAL DESCRIPTION RJ45 PIN
1 DCD/DSR Data carrier detect/data set ready 7
2 RD Receive data 6
3 TD Transmit data 3
4 DTR Data terminal ready 2
5 GND Ground 4 & 5
6 No connection
7 RTS Request to send 1