Version 5.2 Sourcefire 3D System Installation Guide 172
Hardware Specifications
Sourcefire 8000 Series Devices
Chapter 6
Sourcefire 8000 Series Devices
The 8000 Series devices use network modules (NetMods) that contain either
copper or fiber sensing interfaces. The devices can be shipped fully assembled or
you can install the modules. Assemble your device before installing the
Sourcefire 3D System. See the assembly instructions shipped with your modules.
Some 8000 Series devices can be stacked to increase the capability of the
system. For each stacking kit, you replace a NetMod with a stacking module and
cable the devices together using the 8000
Series stacking cable. See Using
Devices in a Stacked Configuration on page 74 for more information.
The 8000 Series device can be delivered on a variety of chassis:
• 3D8120/8130/8140, also known as the 81xx Family, is a 1U chassis and can
contain up to three modules. For the 3D8140 only, you can add a stacking kit
for a total 2U configuration.
• 3D8250, part of the 82xx Family, is 2U chassis and can contain up to seven
modules. You can add up to three stacking kits for a total 8U configuration.
• 3D8260, part of the 82xx Family, is a 4U configuration with two 2U chassis.
The primary chassis contains one stacking module and up to six sensing
modules. The secondary chassis contains one stacking module. You can
add up to two stacking kits for a total 8U configuration.
• 3D8270, part of the 82xx Family, is a 6U configuration with three 2U
chassis. The primary chassis contains two stacking modules and up to five
sensing modules. Each secondary chassis contains one stacking module.
You can add one stacking kit for a total 8U configuration.
• 3D8290, part of the 82xx Family, is an 8U configuration with four 2U
chassis. The primary chassis contains three stacking modules and up to four
sensing modules. Each secondary chassis contains one stacking module.
This model is fully configured and does not accept a stacking kit.
Acoustic noise 64 dBA at full processor load, normal fan operation
Meets GR-63-CORE 4.6 Acoustic Noise
Operating shock Complies with Bellecore GR-63-CORE standards
Airflow
140 ft
3
(3.9 m
3
) per minute
Airflow through the appliance enters at the front and exits at the rear with
no side ventilation.
3D7115 and 3D7125 Physical and Environmental Parameters (Continued)
PARAMETER DESCRIPTION