EasyManua.ls Logo

Source fire Sourcefire 3D System - Page 171

Default Icon
280 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Version 5.2 Sourcefire 3D System Installation Guide 171
Hardware Specifications
Sourcefire 7000 Series Devices
Chapter 6
Fiber 1000BASE-SX SFP Fiber non-bypass capable interfaces with LC connectors
Cable and distance: SX is multimode fiber (850 nm) at 550 m (standard)
200 m (656 ft) for 62.5 μm/125 μm fiber
500 m (1640 ft) for 50 μm/125 μm fiber
Fiber 1000BASE-LX SFP Fiber non-bypass capable interfaces with LC connectors
Cable and distance: LX is single mode fiber (1310 nm) at 10 km for
9 μm/125 μm fiber (standard)
Power supply 450 W dual redundant (1+1) AC power supplies
Voltage: 100 VAC to 240 VAC nominal (85 VAC to 264 VAC maximum)
Current: 3A maximum for 90 VAC to 132 VAC, per supply
1.5A maximum for 187 VAC to 264 VAC, per supply
Frequency range: 47 Hz to 63 Hz
Operating temperature
5
o
C to 40
o
C (41
o
F to 104
o
F)
Non-operating
temperature
-20
o
C to 70
o
C (-29
o
F to 158
o
F)
Operating humidity 5% to 85% non-condensing
Non-operating humidity
5% to 90%, non-condensing with a maximum wet bulb of 28
o
C (82
o
F) at
temperatures from 25
o
C to 35
o
C (77
o
F to 95
o
F)
Store the unit below 95% non-condensing relative humidity. Acclimate
below maximum operating humidity at least 48 hours before placing the
unit in service.
Altitude 0ft (sea level) to 5905 ft (1800 m)
Cooling requirements 900 BTU/hour
You must provide sufficient cooling to maintain the appliance within its
required operating temperature range. Failure to do this may cause a
malfunction or damage to the appliance.
3D7115 and 3D7125 Physical and Environmental Parameters (Continued)
PARAMETER DESCRIPTION

Table of Contents