Version 5.2 Sourcefire 3D System User Guide 240
APPENDIX A
POWER REQUIREMENTS FOR SOURCEFIRE
D
EVICES
The following section describes the power requirements for the Sourcefire 3D
System devices and related information:
• Warnings and Cautions on page 240
• 3D7010/7020/7030 on page 241
• 3D7110/7120 and 3D7115/7125 on page 243
• 3D8120/8130/8140 and 3D8250/8260/8270/8290 on page 245
Warnings and Cautions
This document contains both warnings and cautions. Warnings are safety related.
Failure to follow warnings may lead to injury or equipment damage. Cautions are
requirements for proper function. Failure to follow cautions may result in
improper operation.
Interface Connections
WARNING! The intra-building ports of the equipment or subassembly are suitable
for connection to intra-building or exposed wiring or cabling only. The
intra-building ports of the equipment or subassembly must not be metallically
connected to interfaces that connect outside the plant (OSP) or its wiring. These
interfaces are designed for use as intra-building interfaces only (Type 2 or Type 4
ports as described in GR-1089-CORE, Issue 4) and require isolation from the
exposed OSP cabling. The addition of the primary protectors is not sufficient
protection to connect these interfaces metallically to OSP wiring.