Version 5.2 Sourcefire 3D System Installation Guide 129
Hardware Specifications
Sourcefire Defense Centers
Chapter 6
The DC750 (Rev 2) Physical and Environmental Parameters table describes the
physical attributes and the environmental parameters for the appliance.
Sourcefire DC1500
The DC1500 is a 1U appliance. See the following sections for more information
about the appliance:
DC1500 Chassis Front View on page 130
DC1500 Chassis Rear View on page 132
DC1500 Physical and Environmental Parameters on page 134
DC750 (Rev 2) Physical and Environmental Parameters
PARAMETER DC750 (REV 2)
Form factor 1U
Dimensions (D x W x H) 21.8 in. x 17.25 in. x 1.67 in. (55.37 cm x 43.82 cm x 4.24 cm)
Max weight 33 lbs. (15 kg)
Power supply 250 W power supply for 120 VAC
6.0 Ampere maximum at 110 volts, 50/60 Hz
3.0 Ampere maximum at 220 volts, 50/60 Hz
Operating temperature 50°F to 95°F (10°C to 35°C) with the maximum rate of change not to
exceed 18°F (10°C) per hour
Non-operating
temperature
-40°F to +158°F (-40°C to +70°C)
Non-operating humidity 90%, non-condensing at 95°F (35°C)
Acoustic noise 7.0 dBA in an idle state at typical office ambient temperature (23 +/- 2°C, 73
+/- 4°F
Operating shock No errors with half a sine wave shock of 2G (with 11 msec. duration)
Package shock Operational after 24 in. (60 cm) free fall although cosmetic damage may be
present; chassis weight of 40 to 80 lbs. (18 to 36 kg)
ESD +/- 12 kV for air discharge and 8 K for contact
Airflow Front to back
System cooling
requirements
1660 BTU/hour

Table of Contents