Version 5.2 Sourcefire 3D System Installation Guide 134
Hardware Specifications
Sourcefire Defense Centers
Chapter 6
The DC1500 Serial Port Pin Assignments table describes the signal present on
the DB-9 connector.
DC1500 Physical and Environmental Parameters
The DC1500 Physical and Environmental Parameters table describes the physical
attributes and the environmental parameters for the appliance.
DC1500 Serial Port Pin Assignments
PIN SIGNAL DESCRIPTION
1 DCD Carrier detect
2 RD Received data
3 TD Transmitted data
4 DTR Data terminal ready
5 GND Ground
6 DSR Data set ready
7 RTS Request to send
8 CTS Clear to send
9 RI Ring indicator
DC1500 Physical and Environmental Parameters
PARAMETER DESCRIPTION
Form factor 1U
Dimensions (D x W x H) 27.2 in.x 16.93 in. x 1.7 in. (69.1 cm x 43.0 cm x 4.3 cm)
Max weight 34 lbs. (15.4 kg)
Power supply 600 W power supply for 120 VAC
9.5 Ampere maximum at 110 volts, 50/60 Hz
4.75 Ampere maximum at 220 volts, 50/60 Hz
Operating temperature 50°F to 95°F (10°C to 35°C)
Non-operating temperature -40°F to +158°F (-40°C to +70°C)