Version 5.2 Sourcefire 3D System Installation Guide 145
Hardware Specifications
Sourcefire Series 2 Devices
Chapter 6
3D500/1000/2000 Physical and Environmental Parameters
The following table describes the physical attributes and the environmental
parameters for the appliance.
5 GND Ground
6 DSR Data set ready
7 RTS Request to send
8 CTS Clear to send
9 RI Ring indicator
3D500, 3D1000, and 3D2000 Serial Port Pin Assignments (Continued)
PIN SIGNAL DESCRIPTION
3D500, 3D1000, and 3D2000 Physical and Environmental Parameters
PARAMETER DESCRIPTION
Form factor 1U rack-mounted or desktop device
Dimensions (D x W x H) 6.7 in. x 11.8 in. x 1.25 in. (17 cm x 30 cm x 3.2 cm)
Power Adapter AC Input: 1.6 Ampere maximum at 100-240 Volts, 50/60 Hz
DC Output: 5 Ampere maximum at 12 Volts
Copper 1000BASE-T Gigabit copper ethernet bypass-capable interfaces in a paired configuration
Cable and distance: Cat5E at 50 m
Operating temperature 0°C to 40°C (32°F to 104°F)
Non-operating
temperature
-20°C to 75°C (-4°F to 167°F)
Non-operating humidity 5% to 90%, non-condensing at 45°C (113°F)
Acoustic noise No noise
Cooling requirements Designed to operate in an air-conditioned environment.