Maintenance Waukesha Cherry-Burrell
®
Brand Universal 3 Pump
Page 54 95-03103 11/2018
20. Figure 100 shows both seals installed.
21. Confirm that each seal moves easily in and out by applying
finger pressure to the seal. If the seal does not move,
reassemble the seal and re-confirm.
22. Install the lubricated adjusting ring O-ring onto the shaft
groove.
Figure 100 - Seals installed
Figure 101 - Apply finger pressure
Figure 102 - Install O-ring