EasyManua.ls Logo

ST STM32F105 series

ST STM32F105 series
1128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Connectivity line devices: reset and clock control (RCC) RM0008
125/1128 DocID13902 Rev 15
8.1.3 Backup domain reset
The backup domain has two specific resets that affect only the backup domain (see
Figure 4).
A backup domain reset is generated when one of the following events occurs:
1. Software reset, triggered by setting the BDRST bit in the Backup domain control
register (RCC_BDCR).
2. V
DD
or V
BAT
power on, if both supplies have previously been powered off.
8.2 Clocks
Three different clock sources can be used to drive the system clock (SYSCLK):
HSI oscillator clock
HSE oscillator clock
PLL clock
The devices have the following two secondary clock sources:
40 kHz low speed internal RC (LSI RC) which drives the independent watchdog and
optionally the RTC used for Auto-wakeup from Stop/Standby mode.
32.768 kHz low speed external crystal (LSE crystal) which optionally drives the real-
time clock (RTCCLK)
Each clock source can be switched on or off independently when it is not used, to optimize
power consumption.