PERIODIC MAINTENANCE
2.3
MAINTENANCE AND TUNE-UP PROCEDURES
This section describes the servicing procedures for each item
mentioned in the Periodic Maintenance chart.
AIR CLEANER
Clean every
3
months.
c
If the air cleaner is clogged with dust, intake resistance will be
increased, with a resultant decrease in power output and an
increase in fuel consumption, Check and clean the air cleaner
element in the following manner.
Remove the seat. (p7-6)
Remove the air cleaner case cover
(7:).
Remove the air cleaner element
m.
Separate the polyurethane foam element
3,
element frame
m
and element holder.
0
@
I
Fill a wash pan of a proper size with a non-flammable clean-
ing solvent. Immerse the air cleaner element in the cleaning
solvent and wash it.
Press the air cleaner element between the palms of both
hands to remove the excess solvent: do not twist or wring the
element or
it
will tear.
lmmerse the element in motor oil, and then squeeze out the
excess oil leaving the element slightly wet.
Non-flammable cleaning solvenl
[Bi
MOTUL
AIR
FILTER
OIL or equivalent filter oil