8-1
0
ELECTRICAL
SYSTEM
GENERATOR NO-LOAD PERFORMANCE
Disconnect the generator coupler.
Start the engine and keep it running at
5
000
rlmin.
Using the multi-circuit tester, measure the voltage between
three lead wires.
If
the tester reads under the specified value, replace the gen-
erator with a new one.
@
09900-25008: Multi-clrcuit tester set
I!@
Tester knob indication: Voltage
(-)
Generator no-load performance:
50 V and more at
5
000 rlmln (When engine is cold)
REGULATORIRECTIFIER
Remove the front fender.
(-7-6)
Remove the regulatorlrectifier.
Measure the voltage between the lead wires using the
multi-circuit tester as indicated in the table below. If the volt-
age is not within the specified value, replace the
regulatorlrec-
,
."
tifier with a new one.
@
09900-25008: Multi-circuit tester set
,.
..
[B
Tester knob lndlcatlon: Dlode test
(U)
I
/,
A
..m
Unit:
V
*
More than
1.4
V
(tester's battery voltage)
NOTE:
If the tester reads
1.4
V
and below when the tester probes are
not connected, replace its battery.