Chapter 6 Maintaining and Troubleshooting the TimeProvider
Troubleshooting the TimeProvider
168 TimeProvider User’s Guide 097-58001-02 Revision C – August 2005
OUTBEQPT Output module B was
physically inserted or
removed from the system
EQPTNSA IMMEDNO MJMJMJ
OUTCEQPT Output module C was
physically inserted or v
EQPTNSA IMMEDNO MJMJMJ
OUTDEQPT Output module D was
physically inserted or
removed from the system
EQPTNSA IMMEDNO MJMJMJ
RTMAEQPT Retimer module A was
physically inserted or
removed from the system
EQPTNSA IMMEDNO MJMJMJ
RTMBEQPT Retimer module B was
physically inserted or
removed from the system
EQPTNSA IMMEDNO MJMJMJ
RTMCEQPT Retimer module C was
physically inserted or
removed from the system
EQPTNSA IMMEDNO MJMJMJ
RTMDEQPT Retimer module D was
physically inserted or
removed from the system
EQPTNSA IMMEDNO MJMJMJ
<aid> = IMC
IOC1COMM A communication alarm
with either of the IOC1
modules.
EQPTNSA IMMEDNO MNMNMN
IOC2COMM A communication alarm
with either of the IOC2
modules.
EQPTNSA IMMEDNO MNMNMN
IMCFAIL A summary alarm of
IMC BIST faults
EQPT SA IMMED NO MJ MJ MJ
<aid> = IOC1
IMC1COMM A communication alarm
with the IMC module
and IOC1 module.
EQPTNSA IMMEDNO MNMNMN
IOC1TO2
COMM
A communication alarm
from IOC1 module to
IOC2 module.
EQPTNSA IMMEDNO MNMNMN
Table 6-7. Alarms (Continued)
Alarm ID
Or
CONDTYPE
Alarm Condition
Description
AID
TYPE
Service
Affecting
Error
Delay
Default
Error
Delay
Editable
Alarm Default
Level
SSU PRS SUB