097-58001-02 Revision C – August 2005 TimeProvider User’s Guide 179
Chapter 6 Maintaining and Troubleshooting the TimeProvider
Troubleshooting the TimeProvider
IOCMODE IOC mode is. <mode>
IOCSTATE IOC state has changed, <state>
RESET Module has been reset
IOC Clock Event Conditions
CLKFSTLK Clock entered fast-lock mode
CLKLOCK Clock entered lock mode
SCAVAIL SmartClock algorithm, <value>
IOC Input Event Conditions
CKTIDCHG Input Circuit ID has changed, <cktid>
CRCENA Input CRC has changed, <value>
FRMTYPE Input framing type has changed, <value>
INSTATE Input state has changed, <value>
PRIORITY Priority has changed, <value>
RQLEVEL Received Quality Level has changed, <old quality value>, <new quality value>
QLEVEL User assigned Quality Level has changed, <value>
SPANTYPE Input span type has changed, <value>
SSMBIT E1 SSM bit has changed, <bit position>
SSMENA Input reading of SSM has changed, <value>
THRCHG PM threshold has changed, <PM type>, <value>
IOC Output Event Conditions
CKTIDCHG Output Circuit ID has changed, <cktid>
FREEFLT Free-run output fault strategy has changed, <state>
FRMTYPE Output framing type has changed, <value>
HOLDFLT Holdover output fault strategy has changed, <state>
OUTSTATE Output group state has changed, < value >
OUTMODE Output fault mode has changed, < value >
SYS Event Conditions
BRDGTIM Bridging time has changed, <value>
Table 6-8. Event Code Conditional Descriptions (Continued)
Event ID Event Conditional Description