Pagina 7.24
Figure 7.8-4
7. Remove the lever (g)
since the constraint
shown in Figure, using a 6mm hexagonal
wrench and look the opposite ring nut with a
25mm ring nut spanner and a Ratchet
wrench.
ATTENTION: During reassembly lock
down the ring using a torque wrench
setting of 44Nm.
Figure 7.8-5
The bearings are press assembled and
lock with a Seeger
To reassemble the lever, carry out the above
steps in reverse order.