SYNCHRO EXCITE 2009: Service & maintenance manual - rev. 5.2
Page 7.23
7.8. LEVERS DISASSEMBLY
Figure 7.8-1
Turn off the machine and unplug the mains lead
from the wall outlet.
1. To remove the lever (a), remove the plastic
plug (b)
forcing outwards with a small flat
Phillips screwdriver.
Figure 7.8-2
2. Disconnect the connector (c).
3. Back off the 4 screws (d) with a 6mm
hexagonal wrench.
4. Remove the lever from the machine frame.
ATTENTION: During reassembly, apply
a drop of Loctite and lock down the
screws (d) using a torque wrench setting of
37Nm.
Figure 7.8-3
Carry out the operations described in
paragraphs: 7.7.2. “Brake box cover guard”.
5. Back off the screw inside the housing (e),
with a 3mm hexagonal wrench.
6. Remove the lever (f) from the frame,
direction of arrow.
Continued in following page
→