SYNCHRO EXCITE 2009: Service & maintenance manual - rev. 5.2
Page 6.27
6.10. THERE IS NO RESISTANCE
The machine will not produce resistance if:
• the display board is not receiving a speed signal;
• the brake board is not generating current;
• the brake is defective.
Does the brake board supply
tension at the brake?
THERE IS NO
RESISTANCE
Are the Watt and SPM values
shown on the display different
from zero?
NO
YES
1
Carry out the "The speed
signal is incorrect"
troubleshooting procedure
Replace the brake board
YES
Does the input of brake receive
tension from the brake?
NO
Replace the brake
YES
Replace
ELT-02
cable
NO
3
YES
Is the resistance on the Brake
winding
more or less 5 Ohm?
Replace the brake
NO
2
SELF-POWERED