FAULT . Select t
his menu item to view any instrument faults. If no faults are
currently active, “No Fault” is displayed. If more than one fault is currently active,
press the left ()orright() arrow button to view the additional faults.
EVENT LOG (BY TYPE). Select this menu item and press the ENTER button to
access the EVENT LOG (BY TYPE) submenu, which you can use to view the last
1024 events
,sortedrst by the event type, and then sorted by time within each
event type. (See page 57, EVENT LOG (BY TYPE) submenu.)
EVENT LOG (BY TIME). Select this menu item and press the ENTER button to
access the EVENT LOG (BY TIME) submenu, which you can use to view the last
1024 events sorted by the time of their occurrence. (See page 61, EVENT LOG
(BY TIME)
submenu.)
LAST EVENT BY TYPE. Select this menu item and press the ENTER button to
access the LAST EVENT BY TYPE submenu, which you can use to view the last
instance of each event type, regardless of how many events of other types have
occurred. (See page 61, LAST EVENT BY TYPE submenu.)
CLEAR EVENT LOG. Select this menu item and press the ENTER button to clear
the Event Log. In the conrmation screen, press ENTER to clear the Event Log or
press BACK to return to the STATUS menu.
EVENT LOG (BY TYPE)
submenu
To access this menu, select EVENT LOG (BY TYPE) in the STATUS menu and
press the ENTER button. (See page 56, STATUS menu.) Use this submenu to view
the las t 1024 events, sorted rst by the event type, and then sorted by time within
each event type. (See page 48, How to use the Event Log and event history.)
Press the up ()ordown() arrow button to select a n event type, and then
press the left ()orright() arrow button to view additional events for the
selected event type, if any exist. The display readout shows “No occurrence
f
ound” if no events have occurred for an event type. If an event h as occurred,
the display readout shows the event date and time in the following format:
MM:DD:YYYY HH:MM:SS.
ECO8000 Series Automatic Changeover Unit User Manual 57

Table of Contents

Other manuals for Tektronix ECO8000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix ECO8000 Series and is the answer not in the manual?

Tektronix ECO8000 Series Specifications

General IconGeneral
BrandTektronix
ModelECO8000 Series
CategoryControl Unit
LanguageEnglish

Related product manuals