Commands Listed in Alphabetical Order
Group
Miscellaneous
Syntax
AUXout:SOUrce {ATRIGger|BTRIGger|MAIn|DEL ayed|EVENT|REFOu t}
AUXout:SOUrce?
Related Commands
AUXout?
Arguments
ATRIGger sets the source at the BNC connector to the main trigger.
BTRIGger sets the source at the BNC connector to the delayed trigger.
MAIn sets the source at the BNC connector to the main trigger.
DELayed sets the source at the BNC connector to the delayed trigger.
EVENT sets the source at the BNC connector to a specified event.
REFOut sets the source at the BNC connector to the reference output.
Examples
AUXOUT:SOURCE? might return :AUXOUT:SOURCE ATRIGGER, indicating that
the source at the BNC connector is set to the A trigger.
BELl (No Query Form)
This command was previously used to beep an audio indicator and is provided for
backward compatibility.
Group
Miscellaneous
Syntax
BELl
Examples
BELL is accepted but does nothing.
BUSY? (Query Only)
This query-only command returns the status of the instrument. This command
allows you to synchronize the operation of the instrument with your application
program.
Group
Status and Error
DPO7000, DPO70000/B and DSA7000/B Series Programmer Manual 2-101