Commands Listed in Alphabetical Order
Group
Low Speed Seria
l Trigger
Syntax
TRIGger:A:CAN:IDENTifier: VALue <String>
TRIGger:A:CAN:IDENTifier: VALue?
Arguments
String is up to 29 bits specifying the CAN identifier value.
Examples
TRIGGER:A:CAN:IDENTIFIER: VALUE 1011 sets the CAN trigger identifier
value to 1011.
TRIGGER:A:CAN:IDENTIFIER: VALUE? might return
:TRIGGER:A:CAN:IDENTIFIER :VALUE 10111, indicating that the CAN
trigger identifier value is set to 10111.
TRIGger:A:CAN:PROBE
CAN option only: This command sets or queries the p robing method used to
probe the CAN signal.
Group
Low Speed Serial Trigger
Syntax
TRIGger:A:CAN:PROBE {CANL|CANH|DIFF erential|TX|RX}
TRIGger:A:CAN:PROBE?
Arguments
CANL specifies that the probing method is CANL.
CANH speci
fies that the probing method is CANH.
DIFFerential specifies that the probing method used is differential.
TX specifies that the probing method is TX.
RX specifies that the probing method is RX.
Examples
TRIGGER:A:CAN:PROBE CANH sets the method used to probe the CAN signal to
CANH.
TRIGGER:A:CAN:PROBE? might return TRIGGER:A:CAN:PROB E
DIFFERENTIAL
, indicating that the probing method is differential.
TRIGger:A:CAN:SPEed
CAN option only: This command sets or queries the bit rate of the CAN system.