Commands Listed in Alphabetical Order
to selecting th
e A or B Event (Main) Trigger Setup from the Trig menu, selecting
Pattern as the Trigger Type, selecting Less Than for the Pattern in the Trigger
When settings, and entering a maximum value for Time.
Group
Trigger
Syntax
TRIGger:{A|B}:LOGIc:PATte rn:WHEn:LESSLimit <NR3>
TRIGger:{A|B}:LOGIc:PATte rn:WHEn:LESSLimit?
Related
Commands
TRIGger:{A|B}:LOGIc:PATtern:WHEn:MORELimit
Arguments
<NR3> specifies the amount of time to hold the pattern true.
Examples
TRIGGER:A:LOGIC:PATTERN:W HEN:LESSLIMIT 10.0E+00 sets the
maximum time that the selected pattern may hold true (and generate an A logic
pattern trigger) to 10 s.
TRIGGER:A:LOGIC:PATTERN:W HEN:LESSLIMIT? might return
:TRIGGER:A:LOGIC:PATTERN: WHEN:LESSLIMIT 5.0000E-09, indicating
that the s elected pattern may hold true for up to 5 ns and still generate an A logic
pattern trigger.
TRIGger:{A|B}:LOGIc:PATtern:WHEn:MORELimit
This command sets or queries the minimum time that the selected pattern may be
true and still generate an A or B logic pattern trigger. This command is equivalent
to selecting A or B Event (Main) Trigger Setup from the Trig menu, selecting
Pattern as the Trigger Type, selecting More Than for the Pattern in the Trigger
When settings, and entering a minimum value for Time.
Group
Trigger
Syntax
TRIGger:{A|B}:LOGIc:PATte rn:WHEn:MORELimit <NR3>
TRIGger:{A|B}:LOGIc:PATte rn:WHEn:MORELimit?
Related Commands
TRIGger:{A|B}:LOGIc:PATtern:WHEn:LESSLimit
Arguments
<NR3> specifies the amount of time to hold the pattern true.
2-508 DPO7000, DPO70000/B and DSA7000/B Series Programmer Manual