Oscilloscope Specifications (Cont.)
Voltage and Current Harmonics (THS720P)
Number of Harmonics First 31 harmonics of signal with fundamental frequency between
30 Hz and 450 Hz
Ha
rm
onic
s
Am
plitu
de
Accuracy
Accuracies below are stated as a percent of the fundamental
amplitude and are valid only if peak-to-peak amplitude is
4 divisions and number of averages 16
Fundamental 2 – 11 12 – 21 22 – 31
±2.5% ±2.5% ±4% ±4%
Ha
rm
onic
s
Pha
se
Ar
Fundamental 2 – 11 12 – 21 22 – 31
A
ccu
r
acy
±4 ° ±8 ° ±8 °
THD-F Measurement
Total harmonic distortion relative to the fundamental amplitude
THD-F
V
2
RMS
V
2
f
V
f
or
A
2
RMS
A
2
f
A
f
THD-F Accuracy ±4%
THD-R Measurement Total harmonic distortion relative to the RMS amplitude
THD-R
V
2
RMS
V
2
f
V
RMS
or
A
2
RMS
A
2
f
A
RMS
THD-R Accuracy ±4%
Frequency Accuracy ±0.2% of reading

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix TekScope THS710A and is the answer not in the manual?

Tektronix TekScope THS710A Specifications

General IconGeneral
BrandTektronix
ModelTekScope THS710A
CategoryTest Equipment
LanguageEnglish

Related product manuals