SeaBat Sonar UI - User Manual Appendix Dual head (Master – Slave)
91
The steering value could be
changed at the slave. But as
soon the master steering
value is changed, this will set
the slave steering value with
the master setting.
The coverage value could be
changed at the slave. But as
soon the master coverage
value is changed, this will set
the slave steering value with
the master setting.
The Tracker mode is enabled
from the Master. The master
will control the Slave settings
except the power and gain;
these are controlled by the
slave. It is however not
possible to enable the tracker
conditions as power and gain
from the slave. This is done
by the master.
All slave parameters are set