LLZ/GP
Maintenance Operation and Maintenance
ILS 420
TEST DATA SHEET
6−10 Ed. 01.10SOACa
Test Data Sheet ECU: Control Logic 1 and 2, 3rd Shutdown Logic (with ECU −0003)
Test Item Jumper set Purpose Action Expected Result Passed Failed
Prerequisite:
Equipment in ’Normal’ con-
dition, both TX on, TX1 main
ECU −0003: On LCP: Switch
key lock switch to
’LOCAL’.
− ’Monitor Bypass’ not set
− Status ’NORMAL’ *
ECU J3,J1,J5,J4:
1−2, 9−10
Park position
* If ’Maint. Generate LCP Warning’ in
LRCI Station configuration’ is set to
’yes’, the status is ’Warning’.
ECU Control logic 1
TX1
J3: 5−6, 7−8
J1: 5−6, 7−8
Disablecontr.
log. 2+3rd
shutd.logic:
control logic1
remains ena-
bled
Press LGA1 reset
until a station
alarm is induced
Check voltage at
J3/3 & J1/3: >4 V
− station shutdown (si)* or
− change over to TX2 (du)*
− ECU shows ’Switch Fail’
− Both totem poles are off
(1A/1B)
ECU Control logic 1
TX2
J5: 5−6, 7−8
J4: 5−6, 7−8
Disablecontr.
log. 2+3rd
shutd.logic:
control logic1
remains ena-
bled
Press LGA2 reset
until a station
alarm is induced
Check voltage at
J5/3 & J4/3: >4 V
− station shutdown (dual)
− ECU shows ’Switch Fail’
− Both totem poles are off
(2A/2B)
ECU J3,J1,J5,J4:
1−2, 9−10
Park position − park jumper
− Reset ECU
TX1 and TX2 are on again;
TX1 is main
ECU Control logic 2
TX1
J3: 3−4, 7−8
J1: 3−4, 7−8
Disablecontr.
log. 1+3rd
shutd.logic:
control logic2
remains ena-
bled
Press LGA1 reset
until a station
alarm is induced
Check voltage at
J3/3 & J1/3: >4 V
− station shutdown (si) or
− change over to TX2 (du)
− ECU shows ’Switch Fail’
− Both totem poles are off
(1A/1B)
ECU Control logic 2
TX2
J5: 3−4, 7−8
J4: 3−4, 7−8
Disablecontr.
log. 1+3rd
shutd.logic:
control logic2
remains ena-
bled
Press LGA2 reset
until a station
alarm is induced
Check voltage at
J5/3 & J4/3: >4 V
− station shutdown (dual)
− ECU shows ’Switch Fail’
− Both totem poles are off
(2A/2B)
ECU J3,J1,J5,J4:
1−2, 9−10
Park position − park jumper
− Reset ECU
TX1 and TX2 are on again;
TX1 is main
ECU 3rd Shutdown logic Disconnect cable
at connector J7
(upper) of SYN1.
Causes an executive alarm
condition.
NOTE: The next step will reboot the LCP. Due to missing communications from the LCP during the reboot time, the executive bypass, although asserted, is disabled for the 3rd
control logic. On the ECU, the flashing LED ’Exec. Bypass’ indicates this state. The 3rd shutdown control integrates the duration of an exec. alarm condition while it is
not bypassed. When this integration reaches 6 s, the control then suppresses the clock to the clock detector which triggers a complete station shutdown.
ECU 3rd Shutdown logic
(incl. Clock Detector)
On LCP, Issue a
’Reboot LCP’
command.
Check voltage at
J3/7, J1/7, J5/7 &
J4/7: >4 V
− during LCP reboot, LED
’Exec. Bypass’ goes off
after 10 s, and on again
after 5 s until station
shutdown indicated by
ECU LED ’Exec.On’ and
’Stby On’ off
− ’3rdShutdown Path Off’ lit
− verifies 3rd shutd. logic
as cause of ’off’ condition
Reconnect cable
to J7 of SYN1.
Reset ECU. Clears the ECU.
Set equipment to ’Normal’
condition, both TX ON.
TX1 main.
Set LCP key
switch to
required mode.
Status ’Normal’, equipment is
in service again, no alarms or
alerts indicated.
For this test, 8 jumpers are to be used.
Date: Sign: * (si)= single, (du)= dual