LLZ 421
Operation and Maintenance Alignment Procedure LLZ−1F (Dip./Refl.)
ILS 420
4−7Ed. 01.10
SOAC
d) Click screen button ’Control’ in the start window.
e) Select ’File Transfer’ in menu ’RC Management’. Select ’Copy PC file to RAM’.
f) Copy configuration files (*.sit, *.lke, *.ptt, *.oio) from PC to site.
g) Click ’Reset SITE’ of menu ’RC Management’ to activate entered files and data.
NOTE: The ’Adracs Remote Controlling Software’ is closed due to the reset. It has to be restarted
manually.
h) Run ’Adracs Remote Controlling Software’ again. Perform Login.
i) Click screen button ’Control’ in the start window.
j) Select ’DateTimeREU’ in menu ’RC Management’. Enter date and time and acknowledge with but-
ton ’Set New’. Close window.
k) Click ’Exit’ to close program.
4.2.5 Enter Station Configuration Data
NOTE: Normally this data may be already set in the equipment.
a) Start user program, perform login and select station. The detailed view on the LLZ station appears.
b) Switch both TX on and Set all monitor bypass on.
c) Open the Station Configuration dialog.
d) Enter all required parameters in the dialog window. Verify that the parameter ’Standby configura-
tion’ is set to ’Hot’.
NOTE: Settings in d) must correspond to the settings of the DIP−FIX switch SW1 on ECU board !
To check and modify the ident morse code open dialog ’Transmitter1−Waveform Data#1’ and
’Transmitter2−Waveform Data#1’. Modify entry (up to four characters) in ’Ident Code’ if need be.
e) Switch both TX off.
NOTE: It is recommended for the first setup procedure to note down all settings and values which
have been performed in the individual steps of alignment. This is useful because the val-
ues should be remembered in the setup sequence of the procedure.