LLZ 421
Operation and Maintenance Repair
ILS 420
6−49Ed. 01.10
SOAC
JUMPER POSITION DEFINITION REMARKS
J8 − Used to program EPLD Factory use
J2 − not assembled
J6 − not assembled
J7 − not assembled
J10 − not assembled
J9 1−2
2−3
Path open: closed per optorelay (DMEkey NO)
Path closed: open per optorelay (DMEkey NC)
default (DME_KEY_COM)
−
J11 1−3, 2−4
3−5, 4−6
Path open: closed per optorelay (DMElock NO)
Path closed: open per optorelay (DMElockNC)
default (DME_LOCK_COM)
Set, if DME collocation (LLZ)
J1, J3 to 5 3−4
5−6
7−8
Checks top transistor
Checks middle transistor
Checks bottom transistor
Installing a jumper on J1, J3 to
J5 permit validation of totem
pole check logic by shortening
a selected transistor. Leave
jumper on either end to store.
SWITCH POSITION DEFINITION REMARKS
SW4 /1
/2
/3
/4
/5
/6
/7
/8
closed
open
closed
open
closed
open
closed
open
closed
open
closed
open
closed
open
closed
open
Equipment #1 power on default main
Equipment #2 power on default main
Station interlock bypassed (standalone)
Station interlock enable
Both monitors must alarm bef.station transfer
Either monitor alarm initiates station transfer
Hot standby transmitter monitored
Cold standby transmitter
Field monitoring enabled
Field monitoring disabled
Field monitor has executive control
Field monitoring does not have exec. control
Station shutdown if communications with
RSCU/RSCE is lost (includes LCP if remote
communication is through that: SW2/5 open)
Station maintains same operation if commu-
nications lost to LCP or RSCU/RSCE.
DME shutdown when interlock signal re-
moved (DME remains on even if the ILS is
alarmed off or turned off by the user for
maintenance or such).
DME shutdown when the on−antenna trans-
mitter is shutdown
(DME is on only if ILS exec. TX is on).
Default setting
−
−
Default setting
Default setting (AND−Konf.)
(OR−Konfiguration)
Default setting
−
LLZ only; integrated FFM
Default setting
Depends on application
Default setting
Depends on application
Default setting
Default setting (LLZ)
Depends on application
SW1 key Board reset
SW3 key Lamp test
3b Executive Control Unit (ECU) 120571−0003 2 of 3