21. CHECKS AND ADJUSTMENTS
112
When the instrument is powered off during reticle adjustment the resume function restores the
following screen when the power is turned back on.
When powered off during measurement of point A: point A/staff a measurement screen
When powered off during measurement of point B: point B/staff a measurement screen
When powered off while displaying difference results: difference results screen
Auto focus functionality is not available for the DL-501 Standard. Therefore [FOCUS] is not
displayed in the screen of steps 4 and 14.
Difference calculations
The difference value can be calculated as follows.
Value at position A = {[(1st reading on staff a) - (1st reading on staff b)] + [(2nd reading
on staff a) - (2nd reading on staff b)]} /2
Value at position B = {[(1st reading on staff a) - (1st reading on staff b)] + [(2nd reading
on staff a) - (2nd reading on staff b)]} /2
Difference = absolute value of [(value at position A) - (value at position B)]