Troubleshooting
Topcon Paver System Five Operator’s Manual
9-20
3. If tracker is not working, check that transducer and
foam filter are clean and free from damage. See
Chapter 8 to replace the transducer if necessary.
4. SAS beam and trackers may be too close to reference.
Bottom of tracker must be minimum of 14 inches from
reference.
5. Non-SAS compatible tracker attached to cable. Verify
tracker has SAS compatible decal near S/N label
(Figure 9-4).
Figure 9-4. SAS Compatibility Label
SAS Symptom 4
“SAS is not producing smooth surface.
Probable Cause
Improper setup or Performance Menu Settings.
1. Verify that temperature bails are clean and securely
attached.
2. Verify temperature bail symbol “T” is displayed on
face of Tracker. If not clean or replace transducer. See
Chapter 8 to replace the transducer if necessary.
3. Check that Trackers are between 14 and 24 inches from
reference.
4. If there are gusty winds, lower SAS to get Trackers
closer to reference.
SAS
COMPATIBLE
SAS
COMPATIBLE

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Topcon Paver System 5 and is the answer not in the manual?

Topcon Paver System 5 Specifications

General IconGeneral
BrandTopcon
ModelPaver System 5
CategoryControl Systems
LanguageEnglish

Related product manuals