StartingProblems(continued)
Theenginecranks,butdoesnotstart.
Thefueltankisempty.
Thewiringintheenginecrankcircuitisloose,
corroded,ordamaged;refertotheElectrical
SchematicsinAppendixA—FoldoutDrawings.
Thefuellterisplugged.
Theengineand/orfuelcanbetoocold.
Thecircuitwiringisdamaged.
Theenginefuelpumporcircuit
wiringisdamaged.
Theengineglowcircuitdoesnot
operateproperly.
Theengineorfuelsystemismalfunctioning;
refertoChapter3:DieselEngine(page3–1).
Theglowplugcircuitdoesnotoperateproperly.Thewiringintheengineglowcircuitisloose,
corroded,ordamaged;refertotheElectrical
SchematicsinAppendixA—FoldoutDrawings.
Theengineglowplug(s)is(are)damaged.
Theglowrelayisdamaged.
Thefusiblelinkharnessatthe
enginestartermotorisdamaged.
ThefusesF1,F2,F3,and/orF4
are/isdamaged.
Theenginecranks,butshouldnot,when
thePTOswitchisintheON(up)position.
ThePTOswitchorcircuitwiringisdamaged.
TheStandardControlModuleisdamaged.
Theenginestarts,butstopswhenthekey
switchisreleasedfromtheSTARTposition.
Thecircuitwiringisdamaged.
Thekeyswitchisdamaged.
GeneralRunandTransportProblems
Problem
PossibleCauses
Theenginecontinuestorun,but
shouldnot,whenthekeyswitch
isturnedtotheOFFposition.
Thebatteriesaredischarged.
Thebatterycablesarelooseorcorroded.
ThefuseF1(15A)tothekeyswitch
isdamaged.
Thekeyswitchorcircuitwiringisdamaged.
Theengineshutsoffduringtheoperation,but
itisabletostartagain.
Note:Iftheexcessivecoolanttemperature
causestheenginetoshutdown,theoperator
canstarttheenginebymovingthemachine
toashortdistance.Afterstartingthe
engineinthiscondition,theenginerunsfor
approximately10secondsbeforeitshutsoff
again.
Theparkingbrakeisengaged.
Theoperatorisraisingfromtheseat
(theseatswitchnotfullypressed).
Theseatswitchorcircuitwiringisdamaged.
Thekeyswitchorcircuitwiringisdamaged.
Themachineisoperatedon
aslopewithalowfuellevel.
Theparkingbrakesensororcircuit
wiringisdamaged.
Groundsmaster7210
Page5–17
ElectricalSystem:Troubleshooting
16222SLRevC