NeutralSwitches
g035048
Figure152
1.Leftcover
3.Rightcover
2.Bolts
g033649
Figure153
1.Tractionlever(left)
2.Neutralswitch
TheGroundsmaster7210machineuses2identicalneutralswitches.These
neutralswitchesarenormallyopenandclosewhenthetractionleversareinthe
NEUTRALLOCKposition.Theneutralswitchesarelocatedundertheleftcover
andrightcoverbelowtheoperatorseat(Figure152andFigure153).
TheStandardControlModule(SCM)monitorsthestatusoftheneutralswitches.
IfthekeyswitchisintheONpositionandthe2tractionleversareintheNEUTRAL
LOCKposition,theSCMNeutralinputLEDshouldbeilluminated.Theswitches
areconnectedinseriessothatthe2switchesmustbeclosedfortheneutral
inputtobecompletedfortheSCM.
TestingtheNeutralSwitches
1.Beforeyoudisconnectaneutralswitchfortesting,ensurethatyoutestthe
switchanditscircuitwiringasaSCMinput;refertoStandardControlModule
(page5–3).
Groundsmaster7210
Page5–27
ElectricalSystem:TestingtheElectricalComponents
16222SLRevC