Condition Possible Cause Correction
Cutting units run, but should not, Both the front reels down sensor Check front reels dow
n sensor
when raised and do not shut off and enable switch circuits are and enable switch and replace if
with Enable/Disable switch. closed. necessary.
Check wiring to both switches
and repai
r if necessary.
Hydraulic problem. See Troubleshooting section of
Chapter 4 - Hydraulic System.
Cutting units run, but should not, Enable/Disable switch circuit Test Enable/Disable switch a
nd
when lowered with Enable/ closed. replace if faulty.
Disable switch in disable position.
Check Enable/Disable switch
wiring and repair if faulty.
No cutting units operate in either Seat lifting off seat switch. Instruct operator to sit back in
d
irection (raise and lower seat during operation.
function OK).
Check seat plate hinges and seat
support pin and repair if faulty.
Seat switch circuit open. Check seat switch and replace if
faulty.
Check seat switch wiring and
repair if faulty.
Enable/Disable switch circuit open. Check Enable/Disable switch and
replace if faulty.
Check Enable/Disable switch
wiring and repair if faulty.
Front reels down sensor circuit Check front reels down sensor
open. and replace if faulty.
Check front reels down sensor
wiring and repair if faulty.
Solenoid problem. Test solenoid and replace if faulty.
Check wiring to solenoid and
r
epair if necessary.
Hydraulic problem. See Troubleshooting section of
Chapter 4 - Hydraulic System.
Reelmaster
®