Condition Possible Cause Correction
No cutting units lower. Lower - Mow switch circuit is open. Check for faulty Lower-Mow
switch (joystick).
Check Lower-Mow switch wiring
and repair if faulty.
Problem with solenoid S6. 5A SOL S3/S6 fuse open. If fuses
burn out often, find and correct
cause.
Faulty S6 solenoid coil. Check S6 solenoid wiring and
repair if faulty.
Hydraulic problem. See Troubleshooting section of
Chapter 4 - Hydraulic System.
No cutting units raise. Raise switch circuit open . Test for faulty Raise switch
(joystick).
Check Raise switch wiring and
repair if faulty.
Problem with S7 solenoid. Test solenoid S7 and replace if
faulty.
Check wiring to solenoid S7 and
repair if necessary.
Hydraulic problem. See Troubleshooting section of
Chapter 4
- Hydraulic System.
Left (No. 4) and righ
t (No. 5) front Problem with solenoid S3. Test solenoid S3 and replace if
c
utting units will not raise/lower, faulty.
but other cutting units raise and
lower OK. Check wiring to solenoid S3 and
repair if necessary.
Hydraulic problem. See Troubleshooting section of
Chapter 4
- Hydraulic System.
Center (No. 1) cutting unit will not Problem with solenoid S4. Test solenoid S4 and replace if
raise/lower, but other cutting units faulty.
raise and lower OK.
Check wiring to solenoid S4 and
repair if necessary.
Hydraulic problem. See Troubleshooting section of
Chapter 4 - Hydraulic System.
Reelmaster
®
5100-D Page 5 - 15 Troubleshooting