e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A © 2015 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND TROUBLESHOOTING
8 - 272
[2E65] File creation error due to insufficient USB folder capacity
[2E66] HDD full failure in USB storage
[2EC1] Power failure in USB storage
Classification Error item
File sharing related error Creation of a new file failed because there were too many
files in the USB folder
Check item Measures
Setting Delete unnecessary files in the folder.
Classification Error item
File sharing related error HDD became full while storing data in HDD.
Check item Measures
Setting Delete the job in progress or being set or in the HOLD/
PRIVATE/PROOF/INVALID, and perform it again.
Check if the server or local disk has a sufficient space in disk
capacity.
Check that there is enough space in the USB memory.
Classification Error item
File sharing related error Power failure occurred.
Check item Measures
Setting Check if the power cable is connected properly and inserted
securely. Check if the power voltage is unstable.