TSI Quest EG5 Specifications

General IconGeneral
BrandTSI Quest
ModelEG5
CategoryMeasuring Instruments
LanguageEnglish

Summary

Warnings, Safety Markings, & Standard Information

Warnings concerning safe operation

Important safety precautions to prevent ignition in hazardous atmospheres and ensure intrinsic safety.

Standards

Lists relevant industry standards for personal noise dosimeters and sound exposure meters.

Safety Markings

Details safety markings, intrinsic safety codes, and temperature ranges for the device.

TSI Contact/Service Information

Provides contact details for TSI's service department and technical support.

International Customers

Guidance for international customers on contacting local distributors for support.

SIRA Certification: EC Type-Examination Certificate

Information on the EC Type-Examination Certificate for use in explosive atmospheres.

Chapter 1: Introduction

Dosimetry Basics

Explains noise measurement in workplaces for hearing conservation and exposure assessment.

Overview of Noise Dosimetry

Introduces basic noise dosimetry terms and the Edge dosimeter's purpose.

Noise Dosimeter Operation

Details the components and process of a noise dosimeter measuring sound pressure.

Sound Measurement & Standards

Explains sound pressure measurement in decibels and discusses relevant regulatory standards.

Applications of the Edge Dosimeter

Outlines uses such as personal dosimetry, time-history, survey, and peak measurements.

Noise Assessment Workflow

Covers planning, setup, running studies, analyzing results, and corrective actions.

eg5 Model Overview

Highlights the eg5 model's features, including simultaneous C and A weighted measurements.

Virtual Dosimeter Functionality

Enables three customizable parameter settings for multiple monitoring scenarios.

Chapter 2: Getting Started

Identifying Equipment Components

Familiarizing with the Edge dosimeter, docking stations, and accessories.

Turning the Edge On

Steps to power on the Edge dosimeter and understand its initial display.

LED Indicator Status

Explains the meaning of the three-color LED indicator for operational status.

Navigating the Interface

Using keypad buttons to move through measurement values and battery status.

Powering Off the Edge

Procedure for safely shutting down the dosimeter.

Edge Display and Keypad

Illustrates and explains the functions of the Edge's display screen and keypad buttons.

TSI Detection Management Software (DMS)

Instructions for installing DMS software and understanding docking station functions.

Docking Station Components

Explains LED indicators, connectors, and power adapter assembly for docking stations.

Powering the EdgeDock

Steps to assemble and connect the charger adapter to the EdgeDock.

Charging the Dosimeter

Step-by-step guide to dock and charge the Edge dosimeter on the EdgeDock.

Docking Station Mounting and Storage

Instructions for wall mounting and recommendations for storing the dosimeter.

Chapter 3: Setting up the Edge via DMS

Noise Study Configuration

Customizing parameters like threshold, exchange rate, and filtering for noise studies.

Understanding Stored Data

Defines summary data and time history data, explaining their content.

Logging and Display Views

Details measurements logged and how to customize the dosimeter's display.

Data Log Value Definitions

Defines key data log values like LAS, LASMX, Lcpk, LASMN, and Lavg.

Data Log Value Definitions (Continued)

Defines TWA, SEL, Dose, Projected Dose, Upper Limit, Response Time, and Weighting.

Edge Display Symbols and Descriptors

Explains display symbols and defines Edge measurement descriptors.

Docking and Data Communication

Methods for sending setup data and retrieving measurement data via DMS.

Customizing Setup Parameters in DMS

Guides on configuring dosimeter settings and general edge parameters.

Detailed Dosimeter Settings

Covers settings for Projected Time, Peak Weighting, Dose LED, Threshold, and Criterion Level.

C-A Measurement Setup

Activating C-A measurement via a checkbox in the DMS setup screen.

Dose % Indicator LED Configuration

Configuring LED alarms for dose percentage and heartbeat status.

Display Settings Configuration

Arranging parameters and selecting items to display on the Edge screen.

Security Setting Configuration

Enabling a lock feature to prevent accidental study termination.

Auto Run Setting Configuration

Setting up automatic start and stop configurations for noise studies.

Firmware Update Procedure

Steps to update the Edge dosimeter's firmware using the DMS software.

Miscellaneous Edge Setup

Configuring the instrument's date, time, and identity string.

Saving and Sending Configurations

Managing configuration profiles and transferring them to the Edge.

Chapter 4: Running and Operating

Overview of Running a Study

A quick guide to the steps involved in conducting a dosimetry session.

Positioning the Edge Dosimeter

Instructions on correctly positioning the dosimeter on a shirt for accurate measurements.

Checking Battery Power

How to check remaining battery life using the indicator icon and clock.

Calibrating the Dosimeter

Step-by-step procedure for pre- or post-calibration of the dosimeter.

Resetting the Dosimeter

Instructions for clearing data and resetting the dosimeter via keypad or DMS.

Adjusting Display Contrast

Adjusting the display contrast using the dosimeter's keypad.

Running and Stopping Noise Studies

Steps to start, stop, and understand indicators during noise studies.

Locking and Unlocking the Dosimeter

Enabling the lock feature to prevent interruption and procedures to unlock.

Chapter 5: Viewing Your Studies in DMS

Downloading Data from Edge

Steps to retrieve measurement sessions from the dosimeter to DMS.

Downloading Data in DMS

Selecting data for download and initiating the data transfer process.

Viewing Data in Data Finder Page

Browsing and selecting downloaded studies in the Data Finder page.

Displaying Data in Charts and Tables

Using Analyze or Report View buttons to visualize data.

Report View Functionality

Accessing and printing detailed reports of the Edge measurement data.

Panel Layout View

Using Work Items, Add Panel, and Arrange Panels for data visualization.

Quick Tips for Panel Customization

Resizing panels, customizing chart elements, and exporting data.

Chapter 6: Technical Support/ Customer Service

Replacing Microphone and Windscreen

Instructions for detaching and attaching the microphone and windscreen.

Hard Hat Attachment Kit Installation

Steps for assembling and fitting the hard hat attachment kit.

Contact and Service Information

Provides contact details for technical support and service inquiries.

Returning the Instrument for Service

Guidelines and required information for returning the instrument for repair.

Appendix A: Specifications

Standards and Safety Markings

Lists relevant standards, intrinsic safety codes, and safety markings.

Mechanical and Environmental Specifications

Details housing, size, weight, operating temperature, and humidity.

Power, Electrical, and User Interface Specs

Information on battery life, memory, environmental stabilization, display, and keypad.

EdgeDock1 and EdgeDock5 Details

Describes LED indicators and physical dimensions of docking stations.

Measurement Parameters and Functions

Details displayed data, parameters, calibration, communications, and special functions.

Edge Block Diagram

A schematic illustrating the internal components and their connections within the Edge dosimeter.

Product Warranty Information

Outlines the limited warranty, exclusions, and limitations for the product.

Appendix B: Glossary of Terms

Background Noise Measurement

Explains background noise effects and how to correct measurements.

C-A Measurement and Noise Sources

Defines C-A measurement and procedure for combining noise sources.

Key Measurement Term Definitions

Defines Crest Factor, Criterion Level, Dose, and Exchange Rate.

Calibration and Response Time Definitions

Explains Field Calibration, Response Time, and related terms.

Common Sound Level Definitions

Defines Lavg, Leq, Logging, Lmax, Lmin, and Noise Floor.

Peak, PEL, Projected Time, RMS Definitions

Defines Peak Level, PEL, Projected Time, and RMS.

SEL, Threshold, TWA Definitions

Defines SEL, Threshold, and Time Weighted Average (TWA).

Weighting and Upper Limit Definitions

Defines Weighting (A, C, Z) and Upper Limit (UL).

Appendix C: Measurement Equations

Dose and Projected Dose Equations

Provides equations for calculating Dose, Projected Dose (5-hour, x-hour).

Lavg, Leq, and SEL Equations

Provides equations for calculating Average Level, Equivalent Level, and Sound Exposure Level.

Advanced Measurement Equations

Provides equations for TWA, Exposure, and Integrated Level (LHIST).

Variables Used in Equations

Explains the variables (LS, TC, RTIME, ER, CL, etc.) used in the measurement equations.