D301087 0308 - BL20 CANopen 4-157
I/O-Module Objects
4
Object 6411
hex
- Write Analog Output 16 Bit
The object represents the values for the analog output modules with
16 bits for each channel.
The representation of the current and voltage values as numerical
values is described in detail from a page 126 onward for each value
range.
Table 97:
Objects 6411
hex
Feature Description/ Value
Name Write analog output 16 bit
Object code ARRAY
PDO-mapping Yes
Sub-index 00
hex
Data Type Unsigned8
Access ro
Default value, BL20 No
Sub-index 01
hex
to 8E
hex
Data Type Integer16
Access rw
Default value, BL20 00