D301087 0308 - BL20 CANopen 4-249
I/O-Module Objects
4
Parameter list for the counter module
Module/Parameter
Object Value Meaning
Count mode
Operating mode
Operating mode 5800
hex
000000 Continuous count
A
000001 Single-action count
000010
Periodical count
Release function 0
Abort count operation
A
1 Interrupt count operation
Digital input DI 0
Normal
A
1 Inverted
Function DI 00
Input
A
01 Hardware release (HW
gate)
10
Latch retrigger function
when edge positive
11
Synchronization when edge
positive
Synchronization 0
Single-action
A
1 Periodical
Main count direction 00
None
A
01 Up counting
10
Down counting
A default settings