EasyManuals Logo

Uwatec LUNA 2.0 AI User Manual

Uwatec LUNA 2.0 AI
83 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #22 background imageLoading...
Page #22 background image
22
LUNA 2.0 AI USER MANUAL
2.1.4.1 Dive time warning
In initial factory settings the dive time warning is switched off. The dive time warning can be adjusted from 5 to 195
minutes in 5-minute increments.
2.1.4.2 Dive depth warning
In initial factory settings the dive depth warning is switched off. The dive depth warning can be adjusted from 5 to
100m (20 to 330ft) in 1m/5ft increments.
2.1.4.3 Maximum operating depth warning (MOD)
In initial factory settings the MOD alarm is enabled. Disabling the alarm requires the safety code 313 in order to
prevent accidental switching off.
The MOD alarm uses the maximum ppO
2
value which is given in the gas settings and the default value is 1.4bar.
WARNING
Diving at oxygen partial pressures higher than 1.6bar is extremely dangerous and could lead to severe injury or death.