EasyManuals Logo

Uwatec LUNA 2.0 AI User Manual

Uwatec LUNA 2.0 AI
83 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #67 background imageLoading...
Page #67 background image
67
English
LUNA 2.0 AI USER MANUAL
Note that the CNS O
2
clock is independent of the value of ppO
2
max set by the user. CNS O
2
75% warning and
CNS O
2
100% alarm can be activate during a dive (see chapters CNS O
2
= 75% and CNS O
2
= 100% for more
information), whereas the remaining CNS O
2
value after a dive is shown in the current dive settings display in the
mid-section of the bottom row (4% in below example).
The CNS O
2
clock increases when the oxygen partial pressure is higher than 0.5bar, and decreases when the
oxygen partial pressure is lower than 0.5bar. Hence, while on the surface breathing air you will always be decreasing
the CNS O
2
clock. During the dive, the depth at which 0.5bar is reached for various mixes is as follows:
Air: 13m/43ft
32% O
2
: 6m/20ft
36% O
2
: 4m/13ft
F
NOTE: For oxygen concentrations of 80% and higher, the ppO
2
max is xed at 1.6bar and cannot be changed.
3 .19 Diving with multiple gas mixtures
The LUNA 2.0 AI is equipped with the ZH-L16 ADT MB PMG algorithm. PMG stands for Predictive Multi-Gas,
meaning that when you program more than one gas mixture, the LUNA 2.0 AI will predict the switch to the
higher oxygen concentration gas at the depth that you specied and alert you at all times with a comprehensive
decompression schedule of all the gas mixtures that you programmed.
In other words, you get full credit at any point during the dive for all the extra gas mixtures that you are carrying
with you.
F
NOTE: See chapter Enabling predictive multi-gas mode (PMG) to learn how to enable this mode on your
LUNA 2.0 AI.
WARNING
VERY IMPORTANT!
Diving with multiple gas mixtures represents a much higher risk than diving with a single gas mixture, and mistakes by the
diver may lead to severe injury or death.
During dives with multiple gas mixtures, always make sure you are breathing from the tank that you intend to use. Breathing
from a high oxygen concentration mix at the wrong depth can kill you.
Mark all your regulators and tanks so that you cannot confuse them under any circumstances.
Before each dive and after changing a tank, ensure that each gas mixture is set to the correct value for the corresponding tank.
Get the proper training and certications to make multi-gas dives prior to making them by yourself.
The LUNA 2.0 AI enables you to use up to 3 gas mixtures during the dive.
For oxygen concentrations of 80% and higher, the ppO
2
max is xed at 1.6bar and cannot be changed.
The MOD for tanks 2 and 3 are the switch depths for those gases. This is what the LUNA 2.0 AI uses for its calculations,
warnings, and suggested switch points.
When diving with more than 1 gas mixture, the nitrox reset time function (described in the chapter Nitrox reset time) has the
following effect: gas 1 is set to 21%, gases 2 and 3 are set to OFF.
WARNING
Start breathing from the tank with the new gas mixture before conrming a switch. Always make sure you are switching to the
intended gas. Failure to do so may result in severe injury or death.
The following sections about gas switching are shown with 2 gas mixtures enabled. However, more than two mixes
enabled are working similarly.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Uwatec LUNA 2.0 AI and is the answer not in the manual?

Uwatec LUNA 2.0 AI Specifications

General IconGeneral
BrandUwatec
ModelLUNA 2.0 AI
CategoryDiving Instrument
LanguageEnglish

Related product manuals