vacon • 45 User Interfaces
Figure 17. Programming digital inputs with text keypad
Now, the function External fault close is controlled with a digital signal to digital input DI6 (ter-
minal 16).
Table 18. Programming digital inputs
PROGRAMMING INSTRUCTIONS
Graphical keypad Text keypad
1. Select the parameter and push the
Arrow
right
button.
1. Select the parameter and push the
OK but-
ton.
2. You are now in the
Edit mode as the slot
value
DigIN SlotA. is blinking and under-
lined. (Should you have more digital inputs
available in your I/O, for example, through
inserted option boards in slots D or E, they
can also be selected here.).
2. You are now in the
Edit mode as the letter d
is blinking. (Should you have more digital
inputs available in your I/O, for example,
through inserted option boards in slots D or
E, they can also be selected here.).
3. Push the
Arrow right button again to acti-
vate the terminal value
3.
3. Push the
Arrow right button to activate the
terminal value
3. The letter d stops blinking.
4. Push the
Arrow up button three times to
change the terminal value to
6. Confirm
with OK button.
4. Push the
Arrow up button three times to
change the terminal value to
6. Confirm with
OK button.
5. NOTE! If the digital input DI6 was already
used for some other function a message is
displayed. You might then want to change
either of these selections.
5. NOTE! If the digital input DI6 was already
used for some other function a message will
scroll through the display. You might then
want to change either of these selections.